Chapter 8 - Maintenance
8.8.3.2. CASE 2
Check 5V on STARC (see chapter 8.9, page 232).
Check wiring between STARC J302 and RSI J100.
Change the RSI.
8.8.3.3. CASE 3
Refer to STARC chapter (8.9) if there is an error message from STARC (STARC has the
possibility to shut off 5V on RSI in case of major error).
Check wiring between STARC J302 and RSI J100.
Change the RSI.
Problem:
D52 remains off (5V from STARC).
Solution:
Problem:
D52 is on and D50 remains off.
Solution:
?
?