Chapter 8 - Maintenance
Access to fans
The fan 2(2) is accessed by removing the screws (1) holding the grille and the air filter in place.
The fan 3 (3) for the RPS power supply can be accessed by removing the amplifier for joints 3-6 (see
pages 181 and 182).
To remove it, take out the 2 screws (4).
Figure 8.14
Figure 8.15
DANGER:
When fans are defective, cooled parts can be very hot.
4
2
Fan 2
4
3
Axis 3-6
Fan 3